Vacuum cleaner for dust extraction



The Cyborg X-200 should always be used with a dust extractor.
The X-200 controller can switch a vacuum cleaner on and off automatically at the beginning and at the end of an engraving job.
To do so there is a dedicated 5 VDC outlet at the rear of the machine.
In the above image this is the black plug with the red and black wire.
Do only use a solid state relay.

stofzuiger-groen.jpg If this icon is shown on the virtual pendent, the vacuum cleaner outlet will be powered.
stofzuiger-rood.jpg If this icon is shown on the virtual penden, the vacuum outlet will not be powered.


Every X-200 comes with a short cable with plug to put in the “dust collector” outlet.
The purpose is to switch on and off a 5 VDC solid state relay which in turn can switch a vacuum cleaner on and off.

Clicking on the icon will alternate between the 2 possible choices.

Return to the keypad overview.
Continue to the table of contents.