This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
en:x300:machine_cover_removal [2022/07/05 13:44] jan.vangelder |
en:x300:machine_cover_removal [2023/05/17 10:05] (current) |
||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== Removing the machine | + | ====== Removing the gantry |
---- | ---- | ||
Line 5: | Line 5: | ||
==== Step 1 - Removing the X axis motor cover ==== | ==== Step 1 - Removing the X axis motor cover ==== | ||
- | | {{: | + | |{{: |
- | | {{: | + | |{{: |
- | | | + | | |
- | ==== Step 2 ==== | + | ==== Step 2 - Removing eight of the gantry screws |
+ | |||
+ | {{ : | ||
+ | |||
+ | * Move the gantry to the front of the engraving table and the spindle carriage more or less to the middle of the X axis. | ||
- | * Move the gantry to the front of the engraving table and the spindle carriage more or less to the middle of the X axis.{{ : | ||
* Push the Z-down key on the virtual pendent to lower the spindle until the nose cone touches the engraving table. | * Push the Z-down key on the virtual pendent to lower the spindle until the nose cone touches the engraving table. | ||
- | * Remove 8 of the 10 M4x6 allen screws (indicated in yellow) and keep them apart. **Do not** remove the outer two screws, indicated in red. | ||
- | * To remove these 8 screws, first unscrew the ones you have access to, then move the spindle carriage to the side, in order access the screws which are hidden behind the carriage. | ||
- | * Before loosening the two outer screws (indicated in red), the spindle carriage has to be separated from the X axis movement bracket. (see next page) | ||
- | ==== Step 3 ==== | + | * Remove 8 of the 10 M4x6 allen screws (indicated in yellow) and keep them apart. **Do not** remove the outer two screws, indicated with red arrows. |
- | * Before continuing, remove | + | * To remove these eight screws, first unscrew |
- | * Having lowered | + | |
- | * Remove them with a hex wrench and put them in a safe place. | + | |
- | * After having removed those 2 screws you can move the spindle | + | |
- | ==== Step 4 ==== | + | * Before loosening the two outer screws (indicated in red), the spindle carriage has to be separated from the X axis movement bracket. |
- | * Remove | + | ==== Step 3 - Unmounting |
- | ==== Step 5 ==== | + | * Remove the timing belt from between the motor pulley and the spindle pulley.{{ |
- | * Remove the 2 remaining screws which still hold the X axis linear bearing to the gantry. (these screws are indicated with a red arrow in the image on the right). | + | |
- | * You can then take the linear bearing with thespindle | + | |
+ | * Remove them with a hex wrench and store them in a safe place. | ||
+ | |||
+ | * After removing the two screws, you can move the spindle carriage away to the left from the X movement bracket. | ||
+ | |||
+ | ==== Step 4 - Removing the gantry cover ==== | ||
+ | |||
+ | * Remove the four button head screws which hold the gantry cover on the gantry (indicated with yellow arrows in the 4 images below). \\ \\ {{: | ||
+ | |||
+ | ==== Step 5 - Removing the X axis linear bearing ==== | ||
+ | |||
+ | | ||
+ | |||
+ | * You can then take the linear bearing with the spindle | ||
==== Step 6 ==== | ==== Step 6 ==== | ||
* Holding the spindle carriage and the X axis linear bearing in your hand, lift them up gently. | * Holding the spindle carriage and the X axis linear bearing in your hand, lift them up gently. | ||
+ | |||
* The X axis cover can now be removed vertically. | * The X axis cover can now be removed vertically. | ||
+ | |||
* After having done so, immediately fix the linear bearing to the gantry using the 2 outer screws (see image below) | * After having done so, immediately fix the linear bearing to the gantry using the 2 outer screws (see image below) | ||
+ | |||
* You can fix the spindle carriage back to the X axis bracket, using the 2 allen screws M5x6. The machine is now ready to be serviced on the X axis. | * You can fix the spindle carriage back to the X axis bracket, using the 2 allen screws M5x6. The machine is now ready to be serviced on the X axis. | ||
+ | |||
+ | **Continue to [[: | ||
+ | |||
+ |